KN-HD power frequency interactive type

Features

  1. Dual-core CPU technology, capable of driving motor loads.

  2. Pure sine wave output, with ultra-wide input voltage range.

  3. Startup self-diagnosis function, compatible with generator operation.

  4. Comprehensive protection functions, including overload, output short-circuit, inverter over-temperature, battery undervoltage warning, and battery overcharge protection.

  5. ECO operating mode, offering high efficiency and energy savings to reduce user costs.

  6. RS232 communication interface, supporting remote monitoring.

Product Name:
KN-HD Power Frequency Interactive
Technical parameters
Specification and model
KN-HD/1KVA
KN-HD/1KVAS
KN-HD/2KVA
KN-HD/2KVAS
KN-HD/3KVA
KN-HD/3KVAS
Capacity
1000va/800w
2000va/1600w
3000va/2400w
Battery voltage
24V
36V
72V
72V
72V
96V
Size specification
(W×D×Hmm)
145×355×236
90×430×320
190×380×320
190×430×320
190×380×320
Net weight (Kg)
12
8
28
19
31
21
Input characteristics
Rated voltage
AC220V
Frequency range
45~65Hz
Wiring method
Single-phase grounding type
Power factor
The rated input is ≥0.99
Output characteristics
Output voltage
When the mains power is normal, it is consistent with the mains power. In battery mode, AC220V (1±1%)
Output frequency
When the mains power is normal, it is consistent with the mains power. In battery mode, 50Hz (1±0.25%)
Overload capacity
105%-110% : The UPS will automatically turn on and off after 10 minutes in battery mode, or switch to bypass mode when the input
is normal.
110%-130% : The UPS will automatically turn on and off after 1 minute in battery mode, or switch to bypass mode when the input is
normal.
> 130% : The UPS immediately turns on and off in battery mode or switches to bypass mode when the input is normal
105%-110% : Normal operation and warning sound is emitted;
 110%-130% : The UPS will automatically turn on and off after 1 minute
in battery mode, or switch to bypass mode when the input is normal. 
> 130% : The UPS immediately turns on and off in battery mode
or switches to bypass mode when the input is normal
Current peak ratio
3:1
Output waveform
In battery mode, it is a pure sine wave
Battery characteristics
Battery type
Sealed maintenance-free lead-acid battery
Number of battery cells
2
3
6
6
8
Battery capacity
12V/7Ah
Select as needed
12V/7Ah
Select as needed
12V/7Ah
Select as needed
Charging voltage
DC27.4V±1%
DC41.1V±1%
DC82.2V±1%
DC109.6V±1%
Efficiency
Mains power mode
>88%
>89%
>90%
>87%
>90%
>90%
Battery mode
>88%
>87%
>88%
>83%
>87%
>89%
Environmental characteristics
Relative humidity
10%~90% no fog formation
Ambient temperature
-10℃~45℃
Altitude
<2000m
Noise
At 1 meter, < 50dB
5/5